POWER RECYCLER® For "Burn-in Applications"
|
|
Single Phase, 50 and 60 Hz
Cogenerates power into utility lines for power supply and battery manufacturing companies.
The new inverters, trademarked POWER RECYCLER® span the power range from 3 kW for lower voltage applications to 50 kW for higher voltage, higher power situations. Life testing and burning-in testing are often scheduled both day and night. With a high utilization factor the power recycler can earn back its initial price in savings in electric energy cost and air conditioning cost in less than a year. In parts of the world where the cost of electricity is higher than it is in the United States the payback is even quicker. The Power Recycler® technology is to convert DC power to AC power, and to apply the AC power as a controlled current to the utility line.
|
|
Advanced Features
|
|
Only One Adjustment
|
Simulates Constant Resistance
|
|
Fast Response Through Sampled Data Control System
|
Minimum Parts Count
|
|
Microprocessor / ASIC Controlled
|
IGBT Power Stage
|
|
SPECIFICATIONS
|
|
Input: Any Practical array voltage available. for standard voltage
|
Utility Voltage: Single Phase;
240 VAC, +8%, -12%
|
Output Power: See Table Below
|
|
Efficiency: 92% Typical
|
Current Ripple To Source: 3% RMS. at 120 Hz
|
Current To Utility THD: 3% of Full Load Current
|
|
Power Factor to Utility: .99 Minimum
|
EMI Protection: RFI Filter on Input and Output
|
Humidity: 90% Non Condensing
|
|
Shutdown Protection: Loss of utility, Utility Voltage High, Utility Voltage Low, Loss Of Phase lock, DC Voltage High, DC Voltage Low, Utility Current High
|
Turn-On Characteristics: Bumpless turn-on at zero voltage crossover
|